Technical parameters
1. The parameters
Current channel number | Standard 6 phase |
Number of voltage channels | Standard 6 phase |
Ac current output range | 30A/phase or 180A (six union) |
Dc current output range | 10 the adc/phase |
Ac voltage output range | 120 vac/phase |
Dc voltage output range | 160 VDC/phase |
2. Rated parameters
1) AC current output
6-phase current output (effective value) 0-30A output precision 0.2
The 3-phase current output (effective value) of each phase ranges from 0 a to 60A
6-phase parallel current output (effective value) 0 to 180A
The phase current is allowed to work for a long time (effective value) 10A
Phase current maximum output power 300VA
The maximum output power of the 6-phase parallel current is 1000VA
The maximum output of the 6-phase parallel current allows the working time of 10s
Frequency range (fundamental wave) 20 ~ 1000Hz
Harmonic frequency 1 ~ 20 times
2) DC current output
Current output 0 ~ ±10A/each phase output accuracy level 0.5
Maximum output load voltage 20V
3) AC voltage output
Phase voltage output (effective value) 0 ~ 120V output precision 0.2
Line voltage output (effective value) 0 to 240V
Phase voltage/line voltage output power 80VA / 100VA
Frequency range (fundamental wave) 20 ~ 1000Hz
Harmonic frequency 1 ~ 20 times
4) DC voltage output
Phase voltage output amplitude 0 ~ ±160V output accuracy 0.5
Line voltage output amplitude 0 ~ ±320V
Phase voltage/line voltage output power 70VA / 140VA
5) Switching quantity
Eight switch inputs
Empty contact 1 ~ 20mA, 24V
Potential contact access "0" : 0 ~ +6V; "1" : +11 V to +250 V
4 pairs of switching output DC: 220 V / 0.2a; AC: 220 V / 0.5 A
6) Time measurement range
0.1ms ~ 9999s, the measurement accuracy < 0.1ms