Main body: length 65mm, width 58mm, height 40mm
Main body: length 32mm, width 22mm, height 12mm
Main body 0C73, length 75mm, width 35mm, height 13mm
Main body 0D69, length 15mm, width 10mm, height 5mm
Product features:
Adopting digital and wireless transmission technology, it is completely isolated from the charged body in space, without changing the insulation performance of the tested equipment, and is reliable in use.
The temperature measurement range can reach -25 ℃~125 ℃;
The temperature sensor adopts self powered induction current, battery powered, and RF technology, with a service life of up to 10 years. The three temperature measurement modules are selected and used according to the actual environment.
The induction power supply adopts nano alloy special materials, which makes the induction current more stable.
The battery is powered by a high capacity power battery, which can be used for three to five years in any environment and has stable signal transmission.
RF power supply technology can simultaneously transmit data, with compact size, ultra-thin, and good stability,
Adopting wireless transmission technology. Solved the issues of mutual interference of wireless signals and error correction in data transmission. No interference or impact on primary equipment.
The temperature sensor housing is made of high-temperature and flame-retardant materials.
RS485 communication baud rate: 2400, 4800, 9600bps.
Basic parameters:
Working voltage: AC/DC85V~265V
Operating temperature of the device: -20~+125 ℃;
Storage temperature of the device: -40~+150 ℃;
Short time withstand temperature of temperature sensor: 200 ℃.
Contact temperature measurement points: supports 1024 points, with a standard configuration of 6 points
Transmission distance between sensor and main control device:>150 meters (in open space)
Temperature sensor measurement range: -20 ℃~125 ℃, ± 0.5 ℃
Wireless transmission frequency: 433.05Mhz-434.79Mhz
Wireless transmission power: 14dBm
Wireless reception sensitivity: -94dBm@250kbps
Working life: 10 years
Dielectric strength: The device can withstand 2KV/50Hz/1Min power frequency withstand voltage test
Insulation resistance: ≥ 100M Ω
Electrostatic discharge interference: The main controller can withstand the fourth level electrostatic discharge immunity test specified in the GB/T 17626.2 standard.